Huawei S220-48T4S Best price in Dubai UAE
Data Communication,S220-48T4S,S220-48T4S,S220-48T4S (48x10/100/1000BASE-T ports, 4xGE SFP ports, built-in AC power)
Huawei S220-48T4S Buy with Best Price from authorized supplier for Huaweiproducts in UAE Huawei S220-48T4S eKitEngine Network Switch Distributor for Africa dsrtech.ae, Huawei Dubai
Chassis material Metal
Height [mm] 43.6 mm
Depth [mm] 220.0 mm
Wide [mm] 442.0 mm
Chassis height [U] 1
Weight with packaging [kg(lb)] 3.59 (7.91)
Weight without packaging [kg(lb)] 2.71 (5.97)
Maximum power consumption [W] 43.3
Typical power consumption [W] 36.15
Heat dissipation mode Air cooling for heat dissipation, intelligent
fan speed adjustment
Maximum heat dissipation [BTU/hour] 147.74
Typical heat dissipation [BTU/hour] 123.35
Power supply mode AC built-in
Input voltage range [V] AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz
Rated input voltage [V] AC input: 100–240 V AC; 50/60 Hz
Maximum input current [A] 1.6 A
Number of power slots 0
Number of card slots 0
Memory 2 GB
Flash memory Physical space: 1 GB
Redundant power supply Not supported
Types of fans Built-in
Noise at normal temperature (acoustic power) [dB(A)] 46.6
Noise at normal temperature (acoustic pressure) [dB(A)] 34.6
Airflow direction Air intake from left and air exhaust from right
Storage temperature [C(F)] –40C to +70C (–40F to +158F)
Long-term operating temperature [C(F)] -5C to +50C (23F to 122F) at an
altitude of 0-1800 m (0-5905.44 ft.)
Restriction on the operating temperature variation rate [C(F)] When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1C (1.8F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0C (32F).
The operating temperature ranges from –5C (23F) to +45C (113F) when optical modules with transmission distances greater than or equal to 60 km are used.
The device does not support dying gasp when the ambient temperature is higher than 40C (104F).
Long-term operating relative humidity [RH] 5% RH to 95% RH (non-condensing)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)
MTBF [year] 40.61
MTTR [hour] 2
Availability > 0.99999
Maximum number of physical ports on the entire device 52
Maximum number of 100GE ports 0
Maximum number of 40GE ports 0
Maximum number of 25GE ports 0
Maximum number of 10GE ports 0
Maximum number of GE ports 52
Maximum number of FE ports 48
Downlink ports 48 x 10/100/1000BASE-T ports
Uplink ports 4 x GE SFP ports
USB Not supported
Console port RJ45
Eth Management port Not supported
Service port surge protection [kV] Common mode: +7 kV
Power supply surge protection Differential mode: +6 kV; common mode: +6 kV
RPS input Not supported
PoE Not supported